How to set up your FortiWeb : Auto-learning : Removing old auto-learning data
 
Removing old auto-learning data
There are many reasons why you may want to delete old auto-learning data.
You want to free disk space and system resources.
You installed different web applications on your web servers, and old auto-learning data, based upon the previous installations, no longer applies.
You initiated auto-learning while its URL replacer was misconfigured, and old auto-learning data is malstructured, such as being split between many instances of a dynamic URL, or missing parameters.
You can delete old data. Reports and any profiles generated from the auto-learning profile will then include only subsequently gathered data.
To delete auto-learning data
 
Alternatively, you can remove auto-learning data by, when the auto-learning profile’s report is open, right-clicking the node in the left-hand pane, then selecting Clean Data.
1. Go to Auto Learn > Auto Learn Report > Auto Learn Report.
To access this part of the web UI, your administrator’s account access profile must have Read and Write permission to items in the Autolearn Configuration category. For details, see “Permissions”.
2. Either:
To select one or more reports, mark the check box next to them.
To select all reports, mark the check box in the check box column’s heading.
3. Click Clean Data.
See also
Viewing auto-learning reports
Pausing auto-learning for a URL
How to adapt auto-learning to dynamic URLs & unusual parameters