Device Manager : Managing FortiGate chassis devices : Viewing chassis dashboard : Viewing shelf manager status
 
Viewing shelf manager status
Go to Device Manager > All Chassis and in the Content Pane select the name of a chassis in the list. In the Navigation Pane, select the Shelf Manager item.
Refresh
Select to update the current page.
Shelf Manager
The order numbers of the shelf managers in the chassis.
Model
The shelf manager model.
State
The operation status of the shelf manager.
Temperature
The temperature of the shelf manager.
-48V Bus A
Status of the -48v Bus A: present or absent.
-48V Bus B
Status of the -48v Bus B: present or absent.
Power Used
Power consumed by each shelf manager.
Voltage Sensors
Lists the voltage sensors for the shelf manager.
State
Indicates if the voltage sensors for the shelf manager are detecting a voltage within an acceptable range. OK indicates that all monitored voltages are within acceptable ranges. Below lower critical indicates that a monitored voltage is too low.
Voltage
Voltage value for a voltage sensor.
Edit icon
Select to modify the thresholds of a voltage sensor.