Protection Profiles : Performing a factory reset of SPP settings
 
Performing a factory reset of SPP settings
In some situations, you might want to both reset thresholds for a particular SPP and clear its traffic history. For example:
You have changed the SPP policy network address configuration.
You have deployed a new server or service in the SPP network. Therefore, you want the appliance to recalculate the baseline.
You are conducting a demonstration or test, or you are troubleshooting an issue.
Table 36 summarizes “factory reset” options.
 
Table 36: “Factory reset” options
Task
Menu
Reset the threshold configuration for an SPP.
Protection Profiles > Thresholds > Factory Defaults
Reset the threshold configuration and clear traffic history for an SPP.
See below.
Reset the system to its factory state. All SPPs, statistics, and logs will be deleted.
Before you begin:
You must have Read-Write permission for Protection Profile settings.
To perform a factory reset of SPP threshold settings and traffic history:
1. Go to Protection Profiles > Factory Reset > Factory Reset.
2. Select the SPP you want to reset from the drop-down list.
3. Select the reset check box.
4. Save the configuration.
 
 
To configure with the CLI, use a command sequence similar to the following:
config spp
edit <entry_index>
config ddos spp factoryreset
set reset enable
end