Performing a factory reset of SPP settings
In some situations, you might want to both reset thresholds for a particular SPP and clear its traffic history. For example:
• You have changed the SPP policy network address configuration.
• You have deployed a new server or service in the SPP network. Therefore, you want the appliance to recalculate the baseline.
• You are conducting a demonstration or test, or you are troubleshooting an issue.
Table 35 summarizes “factory reset” options.
Table 35: “Factory reset” options
Task | Menu |
Reset the threshold configuration for an SPP. | Protection Profiles > Thresholds > Factory Defaults |
Reset the threshold configuration and clear traffic history for an SPP. | See below. |
Reset the system to its factory state. All SPPs, statistics, and logs will be deleted. | |
Before you begin:
• You must have Read-Write permission for Protection Profile settings.
To perform a factory reset of SPP threshold settings and traffic history:
1. Go to Protection Profiles > Factory Reset > Factory Reset.
2. Select the SPP you want to reset from the drop-down list.
3. Select the reset check box.
4. Save the configuration.