system : netflow
 
netflow
Use this command to configure sending flow data to a NetFlow collector.
Syntax
config system netflow
set active-flow-timeout <min_int>
set collector-ip <ipv4_addr>
set collector-port <port_int>
set inactive-flow-timeout <sec_int>
set source-ip <ipv4_addr>
set template-tx-timeout <sec_int>
set template-tx-counter <int>
end
Variable
Description
Default
active-flow-timeout <min_int>
Enter the timeout in minutes to report active flows.
30
collector-ip <ipv4_addr>
Enter the NetFlow collector IP address.
0.0.0.0
collector-port <port_int>
Enter the NetFlow collector port number.
2055
inactive-flow-timeout <sec_int>
Enter the timeout in seconds for periodic report of finished flows.
15
source-ip <ipv4_addr>
Enter the source IP address for communication with the NetFlow agent.
0.0.0.0
template-tx-timeout <sec_int>
Enter the timeout in seconds for periodic template flowset transmission.
30
template-tx-counter <int>
Enter the flowset record counter value that triggers resending template flowset records.
20